Skip to content
Monday – Friday: 7 a.m. – 5 p.m.Backflow prevention assembly tester · TX Lic. 000000VerifyPlumbing contractor · TX Lic. 000000VerifyIrrigator · TX Lic. 000000VerifyGeneral liability insurance
3 more licenses
  • Backflow prevention assembly tester · TX Lic. 000000Verify
  • Plumbing contractor · TX Lic. 000000Verify
  • Irrigator · TX Lic. 000000Verify
  • General liability insurance
(806) 555-0102

Services

Six jobs around one valve

Backflow assemblies keep used water from running back into the supply. We test them, fix them, install them and plan around them.

  • Large valves and pressure gauges on industrial pipe risers in a plant room

    Annual test and report

    A gauge test of each assembly, results written on your utility's form and the report filed for you.

    • Every check and relief valve read

    • A copy of the report for you

  • Gloved hands turning the handwheel on a blue flanged gate valve

    Repair and rebuild

    When an assembly fails, we show you the reading, quote the rebuild in writing and retest after the work.

    • Repair price in writing first

    • Retest before the report goes in

  • Brass balancing valves with white handles lined up on a table

    New and replacement assemblies

    Sizing, installing and permitting an assembly where a survey or a failed one shows you need it.

    • Permit pulled where your city asks for one

    • Tested before we leave

  • An impact sprinkler head spraying water over a green lawn

    Irrigation shutoffs and winterizing

    We find, tag and exercise your shutoffs, blow out lines before the first hard freeze and test the assembly at spring start-up.

    • Shutoff locations written on a site card

    • Start-up and winter visits on the calendar

  • Vertical pumps and yellow piping outside an industrial building

    Cross-connection surveys

    A walk of your site to find where water could flow back, and which assemblies protect each spot.

    • A site list you can hand your utility

    • Chemical feeds and well houses included

  • Two pipes with red handwheel valves and copper elbows on a concrete wall

    Test programs for many sites

    One list, one calendar and one folder of reports for HOAs, districts and managers with assemblies at many addresses.

    • Reminders before each due date

    • Tests grouped by route

What you have

Three assemblies you will see on a site

Your utility's notice names the type. Here is how to spot each one and what the test reads.

Three assemblies you will see on a site
What the test readsWhere you find it
Pressure vacuum breaker (PVB)What the test readsWater on, gauge on the test cocks: the air inlet should open at a set pressure and the check should hold.Where you find itOn irrigation lines, mounted above the highest sprinkler head, with a bonnet on top.
Double check valve (DCVA)What the test readsA gauge across each check to read how tightly it holds against reverse flow.Where you find itTwo check valves in a line on low-hazard connections, often at a meter or in a vault.
Reduced pressure assembly (RPZ)What the test readsBoth checks and the pressure at which the relief valve opens.Where you find itTwo checks with a relief valve between them, used where backflow could carry chemicals. The relief port may drip or spit when it fails.

Not sure which assemblies you have?

Send a photo of the one you can see, or the notice from your utility. We will tell you what it is and when it is due.